As a professional high quality 10A Polarized Latching Relay manufacture, you can rest assured to buy 10A Polarized Latching Relay from our factory and we will offer you the best after-sale service and timely delivery.
● 10A switching capability
● High insulation
● Small size and light weight
● RoHS Compliant
As the professional manufacture, we would like to provide you 10A Polarized Latching Relay. Due to our focused approach, timely delivery and ethical business policy, we have been able to gain tremendous success in this domain.
Features
Latching relay.
Small size and light weight.
Contact switching capacity can reach 10A.
PC board mounting.
Ordering Information
1 Part number: NT74L
2 Contact arrangement: A:1A; C:1C
3 Enclosure: S: Wash tight Z: Flux proof
4 Coil rated voltage(V): DC:3,5,12,24
5 Coil NIL:Single coil D: double coils
6 Polarity Nil: standard R: reverse polarity
7 Contact plating NIL:Standard G:Gold plated
Contact Data
Contact Arrangement
1A(SPSTNO) 1C(SPDT(B-M))
Contact Material
AgSnO2
Contact Rating (Resistive)
NO:10A/250VAC,24VDC
NC:8A/250VAC,24VDC
Max. Switching Power
240W 2500VA
Max. Switching Voltage
150VDC 400VAC
Max. Switching Current :10A
Contact Resistance
≤100mΩ
Item 4.12 of IEC 61810-7
Operation
Electrical
5×104
Item 4.30 of IEC 61810-7
Life
Mechanical
5×106
Item 4.31 of IEC 61810-7
Coil Parameter
Dash numbers
Rated voltage VDC
Coil resistance
Ω±10%
Set/Reset voltage VDC
(70% of rated voltage )
Pulse duration ms
Coil power W
Set time ms
Reset time ms
1 Coil
003-250
3
36
2.1
≥30
0.25
≤10
≤10
005-250
8
100
3.5
012-250
12
576
8.4
024-250
24
2300
16.8
2 Coils
003-480
3
2×19
2.1
≥30
2×0.48
≤10
≤10
005-480
5
2×52
3.5
012-480
12
2×300
8.4
024-480
24
2×1200
16.8
CAUTION:
1. When latching relays are installed in equipment, the latch and reset coil should not be powered simultaneously. Coil should not be pulsed with less than the nominal coil voltage and pulse width should be a minimum of three times the specified operate time of the relay. If these conditions are not followed, it is possible for the relay to in be the magnetically neutral position .
2. Switching voltage is for test purpose only and are no to be used as design criteria.
Characteristics
Insulation Resistance
100MΩ min (at 500VDC)
Item 4.11 of IEC 61810-7
Dielectric Strength
Between Contacts
50Hz 1000VAC
Item 4.9 of IEC 61810-7
Between Contact and Coil
50Hz 5000VAC
Item 4.9 of IEC 61810-7
Shock Resistance
Functional: 98m/s²
Item 4.26 of IEC 61810-7
Destructive: 980m/s²
Vibration Resistance
10Hz~55Hz Double amplitude 1.65mm
Item 4.28 of IEC 61810-7
Terminals Strength
10N
Item 4.24 of IEC 61810-7
Ambient Temperature
-40℃~85℃
Relative Humidity
5% to 85%
Item 4.16 of IEC 61810-7
Mass
8g
Item 4.7 of IEC 61810-7
Dimensions(mm)
CAUTION
In case of no tolerance shown in outline dimension: outline dimension ≤1mm tolerance should be ±0.2mm outline dimension >1mm and ≤5mm, tolerance should be ±0.3mm; outline dimension >5mm, tolerance should be ±0.4mm.
For inquiries about automotive relay, industrial relay, latching relay, power relay, signal relay or price list, please leave your email to us and we will be in touch within 24 hours.
We use cookies to offer you a better browsing experience, analyze site traffic and personalize content. By using this site, you agree to our use of cookies.
Privacy Policy