As the professional manufacture, we would like to provide you high quality Dual Coil Latching Relay. And we will offer you the best after-sale service and timely delivery.
● Ultra compact size
● High contact capacity 2A 30VDC
● High Sensitivity
● Low power consumption
● Conforms to FCC Part 68 1500V Surge and Dielectric 1000VAC
● RoHS Compliant
You are welcomed to come to our factory to buy the latest selling, low price, and high-quality Dual Coil Latching Relay. Casa Relay adhered to he principle of "quality is the life", to provide customers with the best quality, the most competitive prices, the first-class after-sales service.
Features
DIL pitch terminals. High sensitivity :0.14W or 0.10W nominal power.
Conforms to FCC Part 68 1.5kV surge and dielectric 1000VAC.
Monostable, single or double coil latching relay .
2 Operating function:
NIL: Single Side Stable
L:1 Coil Latching; K:2 Coil Latching
3 Coil rated voltage(V): DC:3,4.5,5,6,9,12,24
4 Contact material: NIL: AgPd W: AgNi
Contact Data
Contact Arrangement
2C(DPDT(B-M)) (Bifurcated Crossbar)
Contact Material
AgPd(Au plated ) AgNi(Au plated)
Contact Rating (Resistive)
1A,2A/30VDC; 0.5A/125VAC
Max. Switching Power
60W 62.5VA
Min. Switching Load 0.01mA/10mV(Reference Value)
Max. Switching Voltage
220VDC 250VAC
Max. Swit ching Current:2A
Contact Resistance
≤50mΩ
Item 4.12 of IEC 61810-7
Operation Life
Electrical
2×105 (DC AgPd);1×105(DC AgNi)
1×105(AC)
Item 4.30 of IEC 61810-7
Mechanical
1×108
Item 4.31 of IEC 61810-7
CAUTION:
Relays previously tested or used above 10mA resistive at 6V maximum DC or peak AC open circuit are not recommended for subsequent use in low level applications.
Coil Parameter
Dash numbers
Coil voltage VDC
Coil resistance
Ω ± 10%
Pick-up voltage VDC(max) (75%of rated voltage )
Drop-out voltage VDC(min) (10% of rated voltage)
Coil power W
Operate time ms
Release time ms
Rated
Max.
P-003
3
7.5
64.3
2.25
0.3
0.14
Approx.2
Approx.1
P-004
4.5
11.25
144.6
3.38
0.45
0.14
P-005
5
12.5
178
3.75
0.5
0.14
P-006
6
15.0
257
4.50
0.6
0.14
P-009
9
22.5
579
6.75
0.9
0.14
P-012
12
30.0
1028
9.00
1.2
0.14
P-024
24
48.0
2880
18.0
2.4
0.20
1 Coil Latching
Set
Reset(Max)
Set
Reset
PL-003
3
8.7
90
2.25
-2.25
0.10
Approx.2
Approx.2
PL-004
4.5
13.0
202.5
3.38
-3.38
0.10
PL-005
5
14.5
250
3.75
-3.75
0.10
PL-006
6
17.4
360
4.50
-4.50
0.10
PL-009
9
26.1
810
6.75
-6.75
0.10
PL-012
12
34.8
1440
9.00
-9.00
0.10
PL-024
24
57.6
3840
18.0
-18.0
0.15
2 Coils Latching
Set Coil
Reset Coil
Set
Reset(Max)
Set
Reset
PK-003
3
6
45
45
2.25
2.25
0.20
Approx.2
Approx.2
PK-004
4.5
9
101
101
3.38
3.38
0.20
PK-005
5
10
125
125
3.75
3.75
0.20
PK-006
6
12
180
180
4.50
4.50
0.20
PK-009
9
18
405
405
6.75
6.75
0.20
PK-012
12
24
720
720
9.00
9.00
0.20
PK-024
24
36
1920
1920
18.0
18.0
0.30
CAUTION:
1.The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay.
2.Pickup and release(reset) voltage are for test purposes only and are not to be used as design criteria.
3.When latching relays are installed in equipment, the set and reset coil should not be powered simultaneously. Coil should not be pulsed with less than the nominal coil voltage and pulse width should be a minimum of three times the specified operate time of the relay. If these conditions are not followed, it is possible for the relay to be in the magnetically neutral position .
In case of no tolerance shown in outline dimension: outline dimension ≤1mm tolerance should be ±0.2mm outline dimension >1mm and ≤5mm, tolerance should be ±0.3mm; outline dimension >5mm, tolerance should be ±0.4mm.
For inquiries about automotive relay, industrial relay, latching relay, power relay, signal relay or price list, please leave your email to us and we will be in touch within 24 hours.